Environmental Impacts of Energy Use: Air Pollutants, Greenhouse Gases, Emission Factors and Inventories
2. Greenhouse gases, sources and CO₂-equivalent
Greenhouse gases absorb outgoing infrared radiation and warm the lower atmosphere. The main ones from human activity are carbon dioxide (CO₂), methane (CH₄), nitrous oxide (N₂O) and the fluorinated gases (hydrofluorocarbons, perfluorocarbons, sulphur hexafluoride). Water vapour is also a greenhouse gas, but its amount responds to temperature and is not set directly by emissions.
- CO₂: burning coal, oil and gas (the largest source in energy systems), and the calcination of limestone in cement-making, which releases CO₂ from the raw material itself.
- CH₄: livestock, rice paddies, landfills, leakage and venting in coal mining and in oil and gas systems, and incomplete combustion.
- N₂O: fertilised soils, some industrial processes such as nitric-acid production, and some combustion processes.
- Fluorinated gases: refrigerants and foam-blowing agents, and SF₆ as an insulating gas in electrical switchgear; present in tiny amounts but long-lived and strongly absorbing.
Gases are put on a common scale with the global warming potential (GWP): the warming caused by 1 kg of the gas over a stated time horizon (commonly 100 years) relative to 1 kg of CO₂, so GWP(CO₂) = 1. The CO₂-equivalent of an emission is CO₂e = Σ mᵢ × GWPᵢ. GWP values depend on the horizon chosen and on which scientific assessment they are taken from, so a question must state them. Worked, with GWP(CH₄) = 28 and GWP(N₂O) = 265 as given: 1000 kg CH₄ and 10 kg N₂O are 28 000 + 2650 = 30 650 kg CO₂e.
3. Stoichiometric emission calculations
Take atomic masses C = 12, H = 1, O = 16, S = 32 (kg/kmol). Each complete reaction fixes the emission per unit of fuel element: C + O₂ → CO₂ gives 44/12 = 3.667 kg CO₂ per kg carbon; S + O₂ → SO₂ gives 64/32 = 2 kg SO₂ per kg sulphur (if all sulphur is oxidised and none is retained in ash); CH₄ + 2O₂ → CO₂ + 2H₂O gives 44/16 = 2.75 kg CO₂ per kg methane. For a coal with 72 % carbon, burning 200 kg/h emits 200 × 0.72 × 44/12 = 528 kg CO₂/h.
Flue-gas composition. Take air as 21 % O₂ and 79 % N₂ by volume (3.76 kmol N₂ per kmol O₂). For methane with theoretical air: CH₄ + 2O₂ + 7.52N₂ → CO₂ + 2H₂O + 7.52N₂. Dry products are 1 + 7.52 = 8.52 kmol, so dry CO₂ = 1/8.52 = 11.74 %. With 20 % excess air the extra 0.4 kmol O₂ (and 1.504 kmol N₂) appear unreacted: dry products = 1 + 0.4 + 9.024 = 10.424 kmol, CO₂ = 9.59 % and O₂ = 3.84 %. Excess air dilutes every pollutant, so measured concentrations must be corrected to a common oxygen level.
- ppm to mass: for a gas of molar mass M, C (mg/Nm³) = ppm × M/22.414, where 22.414 L/mol is the molar volume at 0 °C and 1 atm (“normal” conditions). 500 ppm SO₂ (M = 64) is 500 × 64/22.414 = 1428 mg/Nm³.
- Oxygen correction: C_ref = C_meas × (21 − O₂,ref)/(21 − O₂,meas), with oxygen in % by volume on the same (dry) basis. 300 mg/Nm³ NOx measured at 6 % O₂ is 300 × 18/15 = 360 mg/Nm³ at a 3 % O₂ reference, since the dilution by excess air is removed.
4. Emission factors and inventories
An emission factor (EF) is the mass of a pollutant released per unit of an activity: kg CO₂ per GJ of fuel, g NOx per kWh of electricity, kg SO₂ per tonne of coal. An inventory multiplies each activity (the quantity of fuel burned, electricity bought, product made) by its EF and adds up: E = Σ Aᵢ × EFᵢ. If a control device of removal efficiency η is fitted, E = A × EF × (1 − η).
For greenhouse-gas inventories of an organisation, emissions are grouped by the widely used scope convention: Scope 1 direct emissions from sources the organisation owns (boilers, furnaces, vehicles, process emissions); Scope 2 indirect emissions from the generation of the electricity, steam or heat it buys; Scope 3 all other indirect emissions in the value chain (purchased materials, transport, use of products). A purchased kWh carries the grid emission factor, the average kg CO₂ per kWh of the supply, so cutting purchased electricity cuts Scope 2 by that factor per kWh.
| Source | Activity × factor | Emission |
|---|---|---|
| Scope 1: gas boiler | 10 000 GJ × 56 kg/GJ | 560 t CO₂ |
| Scope 2: grid electricity | 2.0 × 10⁶ kWh × 0.82 kg/kWh | 1640 t CO₂ |
| Total | 560 + 1640 | 2200 t CO₂ |
| After saving 10 % of grid electricity | 0.10 × 1640 | 164 t saved |
5. Control efficiency and the precipitator
The removal efficiency of a control device is η = (C_in − C_out)/C_in = 1 − C_out/C_in, or equivalently by mass flow. Devices in series combine through their penetrations: the fraction passing is the product of the individual (1 − η), so η_total = 1 − (1 − η₁)(1 − η₂). A cyclone of 70 % followed by a fabric filter of 99 % passes 0.30 × 0.01 = 0.003, so η_total = 99.7 %. A scrubber taking 90 % of 12 t/h of SO₂ leaves 12 × 0.10 = 1.2 t/h to the stack.
In an electrostatic precipitator the particles are charged and drawn to collecting plates. For ideal plug flow with migration velocity w towards the plates, collecting area A and gas flow Q, the Deutsch–Anderson equation gives η = 1 − exp(−wA/Q). The exponent wA/Q = 4 gives η = 1 − e⁻⁴ = 98.2 %; doubling the plate area to wA/Q = 8 gives 99.97 %. Efficiency rises with area and falls with gas flow, and fine particles with low w need large plate area.
Key takeaways
- SOx is fuel-bound (S + O₂ → SO₂, 2 kg SO₂ per kg S); NOx is mostly thermal and falls with lower flame temperature; CO signals incomplete combustion; particulates come from ash and soot.
- Greenhouse gases are CO₂, CH₄, N₂O and fluorinated gases; GWP puts them on a CO₂ scale per kilogram, and CO₂e = Σ m × GWP with the GWP values stated.
- Stoichiometry fixes CO₂ at 44/12 kg per kg carbon; dry CO₂ in flue gas falls as excess air rises, and concentration is corrected to a reference O₂ by (21 − O₂,ref)/(21 − O₂,meas).
- An inventory is E = Σ activity × emission factor, with (1 − η) for control; CO₂ factors are firm, NOx and CO factors depend on combustion conditions.
- Scope 1 is direct, Scope 2 is purchased electricity, steam or heat, and Scope 3 is the rest of the value chain.
- Control efficiencies in series combine through penetrations; the precipitator obeys η = 1 − exp(−wA/Q); each device removes only the pollutant class it is built for.
Practice questions (16)
Attempt each one before opening the answer. Every explanation names the tempting wrong option as well as the right one, because that is where marks are lost.
A gas-fired furnace is modified by recirculating part of the flue gas into the combustion air, which lowers the peak flame temperature. The pollutant most directly reduced is
Show answer
Answer: D — thermal NOx, because N₂ oxidation rises steeply with flame temperature
Thermal NOx forms from atmospheric N₂ and O at high temperature and is steeply temperature dependent, so cooling the flame cuts it. SO₂ is fixed by fuel sulphur, and CO₂ by fuel carbon, whatever the flame temperature; gas fuel has no mineral ash to reduce.On a boiler, as the excess air is reduced below a certain level the CO in the flue gas rises sharply. The most direct explanation is that
Show answer
Answer: A — the available oxygen and mixing are no longer enough to oxidise all the CO to CO₂
Below the needed air the carbon cannot all reach CO₂, so CO (and soot) appear; this is why oxygen trim stops short of zero excess air. The other mechanisms do not occur: sulphur gives SO₂, and N₂ does not form CO.A coal contains 2.0 % sulphur by mass, all of which is oxidised to SO₂ with none retained in the ash. Atomic masses: S = 32, O = 16. The SO₂ released per tonne of coal burned is
Show answer
Answer: B — 40 kg, since SO₂ is twice as heavy as its sulphur
Sulphur in 1 t is 20 kg. S + O₂ → SO₂ gives 64/32 = 2 kg SO₂ per kg S, so 40 kg. Quoting the sulphur mass itself forgets the added oxygen.An analyser reads 300 mg/Nm³ of NOx in dry flue gas containing 6 % O₂ by volume. A regulation quotes NOx at a 3 % O₂ reference, using C_ref = C_meas × (21 − O₂,ref)/(21 − O₂,meas). The reference-basis concentration is
Show answer
Answer: B — 360 mg/Nm³, from 300 × 18/15
(21 − 3)/(21 − 6) = 18/15 = 1.2, so 300 × 1.2 = 360 mg/Nm³. The sample was diluted by excess air (6 % O₂ against 3 %), so removing the dilution raises the number; the inverted ratio would lower it, and the simple oxygen ratios have no basis in the correction.The CO₂-equivalent of a greenhouse-gas emission is obtained by
Show answer
Answer: A — multiplying each gas’s emitted mass by its GWP and summing
CO₂e = Σ m × GWP expresses each gas as the mass of CO₂ with the same warming over the stated horizon. Unweighted addition ignores the large differences in warming per kg, and molar or carbon fractions measure composition, not warming.Under the scope convention for greenhouse-gas inventories, the emissions arising at a power station from the electricity a factory buys from the grid are counted in the factory’s inventory as
Show answer
Answer: B — Scope 2, as indirect emissions from purchased electricity
Purchased electricity, steam and heat form Scope 2; direct emissions from owned boilers and vehicles are Scope 1, and the factory is responsible for Scope 2 through its consumption even though it has no stack for them.Which of the following pairs of control technology and the pollutant it is mainly designed to remove is correct?
Show answer
Answer: D — selective catalytic reduction with ammonia, for NOx
SCR reduces NOx to N₂ and water over a catalyst using ammonia. Precipitators, fabric filters and cyclones collect particles and do nothing for gases such as SO₂, NOx or CO.A plant manager notes that a published CO₂ emission factor for a fuel can be applied to any boiler, but a published NOx factor gives a poor estimate for a particular boiler. The reason is that
Show answer
Answer: C — CO₂ follows from the fuel carbon, while NOx depends on burner design, load, excess air and flame temperature
Complete combustion fixes CO₂ per unit of fuel carbon; NOx is set by combustion conditions, so a generic factor can be far off. NOx forms from both fuel nitrogen and air nitrogen, and CO₂ is formed in all hydrocarbon combustion.Which of the following statements about particulate matter are correct?
Show answer
Answer: A — PM₂.₅ refers to particles of aerodynamic diameter up to 2.5 µm; B — Fine particles penetrate deeper into the lungs than coarse particles; D — A cyclone separator is less effective on fine particles than on coarse ones
PM sizes are defined by aerodynamic diameter, finer particles go deeper, and cyclones rely on inertia, which is weak for small particles. Soot from incomplete combustion of oil, gas and biomass is also particulate matter.Which of the following statements about greenhouse-gas sources are correct?
Show answer
Answer: A — Methane is emitted from landfills, rice paddies and livestock; B — Nitrous oxide is emitted from fertilised soils; D — Cement manufacture releases CO₂ from the limestone as well as from the fuel
Landfills, paddies and livestock are standard methane sources, fertilised soils give N₂O, and calcination of limestone adds process CO₂ in cement. CO₂ also arises from such process sources, so the claim that it comes only from fuel is false.Which of the following statements about combustion emissions are correct?
Show answer
Answer: A — Lowering the peak flame temperature by staging or flue-gas recirculation reduces thermal NOx; C — Burning a fuel of lower sulphur content reduces SO₂ emission in proportion; D — For complete combustion the CO₂ released per unit mass of fuel carbon is fixed by stoichiometry
Thermal NOx falls with flame temperature, SO₂ is proportional to fuel sulphur, and CO₂ is 44/12 per unit carbon in complete combustion. More air tends to reduce CO but can raise NOx where the added oxygen outweighs the cooling, so the claim of always reducing both is false.A factory in a year buys 2.0 × 10⁶ kWh of grid electricity and burns 10 000 GJ of natural gas. Take the grid emission factor as 0.82 kg CO₂ per kWh and the natural-gas factor as 56 kg CO₂ per GJ. The total annual CO₂ emission counted in its inventory is ____ tonnes (nearest integer).
Numerical answer — type the value.
Show answer
Answer: 2200
Electricity: 2.0 × 10⁶ × 0.82 = 1.64 × 10⁶ kg = 1640 t. Gas: 10 000 × 56 = 5.6 × 10⁵ kg = 560 t. Total = 2200 t CO₂. Forgetting the division by 1000 to convert kg to tonnes is the usual slip.A coal-fired boiler burns 500 t of coal per hour containing 1.2 % sulphur by mass. All sulphur is oxidised to SO₂ (S = 32, O = 16), and a flue-gas desulphurisation unit removes 90 % of the SO₂. The SO₂ released to the atmosphere is ____ t/h (one decimal place).
Numerical answer — type the value.
Show answer
Answer: 1.2
Sulphur = 500 × 0.012 = 6 t/h. SO₂ formed = 6 × 64/32 = 12 t/h. Released = 12 × (1 − 0.90) = 1.2 t/h. Stopping at 12 t/h omits the scrubber, and using 6 t/h forgets the oxygen.Methane burns completely with 20 % excess air: CH₄ + 2(1.2)(O₂ + 3.76N₂) → products. Treat air as 21 % O₂ and 79 % N₂ by volume. The volume percentage of CO₂ in the dry flue gas is ____ % (one decimal place).
Numerical answer — type the value.
Show answer
Answer: 9.6
Air supplied: 2.4 kmol O₂ with 9.024 kmol N₂. Dry products: CO₂ 1; O₂ left 2.4 − 2 = 0.4; N₂ 9.024; total 10.424 kmol. CO₂ = 1/10.424 = 9.59 %, so 9.6. The theoretical-air value is 11.7 %, which this excess dilutes.A site emits 1000 kg of CH₄, 10 kg of N₂O and 5000 kg of CO₂ in a year. Taking GWP values over the chosen horizon as 28 for CH₄ and 265 for N₂O (and 1 for CO₂), the total emission is ____ kg CO₂-equivalent (nearest integer).
Numerical answer — type the value.
Show answer
Answer: 35650
CO₂e = 5000 × 1 + 1000 × 28 + 10 × 265 = 5000 + 28 000 + 2650 = 35 650 kg. Adding the raw masses gives only 6010 kg, which ignores the weighting.An electrostatic precipitator treats a gas flow of 60 m³/s. It has a total collecting plate area of 3000 m² and an effective migration velocity of 0.08 m/s. Using the Deutsch–Anderson equation η = 1 − exp(−wA/Q), the collection efficiency is ____ % (one decimal place).
Numerical answer — type the value.
Show answer
Answer: 98.2
wA/Q = 0.08 × 3000/60 = 4.0. η = 1 − e⁻⁴ = 1 − 0.018316 = 0.98168 = 98.2 %. Using wA/Q directly as a fraction is not possible here, since it exceeds 1.