Modelling a Control System: Feedback, Transfer Functions and Response
1/(1 + sτ) to the algebra, which is why this section sits comfortably beside Networks and Signals rather than apart from it. The second is to identify the standard form before computing anything: recognise ω_n²/(s² + 2ζω_n s + ω_n²) and eight time-domain and frequency-domain results follow from two numbers. The paper is 65 questions, 100 marks, 180 minutes, with General Aptitude taking 10 questions for 15 marks; a wrong MCQ costs a third of that question's marks, while MSQ and NAT carry no negative marking, and since most control questions are numerical you should be leaving no NAT blank.Transfer Functions, Poles and the Standard Second Order Form
For a linear time-invariant system the transfer function is the ratio of the Laplace transform of the output to that of the input with all initial conditions zero, and that last clause is not decoration: it is the reason the transfer function describes the forced response and says nothing directly about where the system started. Its denominator set to zero is the characteristic equation, whose roots are the poles, and the poles alone decide the shape of the natural response — a real pole at −a contributes e^(−at), a complex pair at −σ ± jω contributes e^(−σt) times a sinusoid at ω, and a pole in the right half plane contributes a growing exponential. Zeros do not change which exponentials appear; they change how much of each appears, and a zero in the right half plane produces the characteristic initial undershoot of a non-minimum-phase system.
Almost every examinable result in this section is stated for the standard second-order form T(s) = ω_n²/(s² + 2ζω_n s + ω_n²), so learn to read ω_n and ζ off a given denominator before doing anything else. Take T(s) = 25/(s² + 6s + 25). Matching the constant term gives ω_n² = 25, so ω_n = 5 rad/s; matching the s term gives 2ζω_n = 6, so ζ = 6/10 = 0.6. The poles are then at −ζω_n ± jω_n√(1 − ζ²) = −3 ± j4, and the damped natural frequency ω_d = 4 rad/s is the imaginary part — a useful check, since 3² + 4² = 5² means the poles lie on a circle of radius ω_n at an angle whose cosine is ζ. That geometric reading is worth keeping: distance from the origin is ω_n, and the cosine of the angle from the negative real axis is ζ, which is how a root-locus plot in the next chapter is read for damping at a glance.
Range of ζ | Pole positions | Step response |
|---|---|---|
Undamped, ζ = 0 | A pair on the imaginary axis at ± jω_n | Undamped, oscillates for ever at ω_n |
Underdamped, 0 < ζ < 1 | Complex pair at −ζω_n ± jω_n√(1 − ζ²) | Underdamped: overshoots, then rings down |
Critically damped, ζ = 1 | Two coincident real poles at −ω_n | Critically damped: fastest with no overshoot |
Overdamped, ζ > 1 | Two distinct real poles, one dominant | Overdamped: no overshoot, and slow |
−1 ± j2 and a third pole at −20, the pair is dominant and the second-order formulas apply with the error of a few per cent. The usual threshold quoted is a factor of five or more in real part. The same logic handles a pole and a zero that nearly cancel: (s + 3.1)/(s + 3.0) contributes almost nothing and can be struck out. What the approximation must never be used for is stability — a far-off pole in the right half plane dominates everything eventually, however small its residue, so approximate the response but never the sign.Block Diagram Reduction, Done in an Order That Works
Three rules do most of the work. Blocks in cascade multiply. Blocks in parallel into a summing junction add. And a negative feedback loop of forward gain G and feedback gain H collapses to G/(1 + GH), with the sign in the denominator opposite to the sign at the summing junction — positive feedback gives G/(1 − GH), which is where a sign slip costs a whole question. The order to apply them in is the part worth practising: always reduce the innermost loop first, because an inner loop that is still open blocks every outer simplification, and because reducing outwards means you never have to move a block past anything.
Work a two-loop example all the way to a standard form. The forward path is an amplifier-integrator G_1 = 10/s followed by a plant G_2 = 1/(s + 2). Around G_2 alone there is a minor negative feedback loop with H_1 = 0.5 — a tachometer, say. Around the whole thing there is unity negative feedback. Reduce the inner loop first: G_2/(1 + G_2H_1) = [1/(s + 2)]/[1 + 0.5/(s + 2)] = 1/(s + 2.5), which is the same plant with its pole pushed left, from −2 to −2.5. That is what minor-loop feedback does physically, and it is worth noticing before the algebra buries it. The forward path is now 10/[s(s + 2.5)], and closing the unity loop gives T(s) = 10/[s(s + 2.5) + 10] = 10/(s² + 2.5s + 10).
Read the standard form off it at once. ω_n = √10 = 3.162 rad/s and 2ζω_n = 2.5, so ζ = 2.5/6.325 = 0.395 — underdamped, and badly enough that the step response overshoots by exp(−ζπ/√(1 − ζ²)) = 25.9 %. That number is the whole reason the minor loop was there: raise H_1 and the inner pole moves further left, ζ rises and the overshoot falls, at the cost of a slower loop. Two reduction rules for the awkward diagrams are worth stating exactly, because their asymmetry is a favourite trap. To move a block G backwards past a summing junction, the other branch entering that junction must be divided by G. To move a take-off point backwards past a block G, the branch leaving it must be multiplied by G. Those two go opposite ways, and a diagram that has been rearranged in the wrong direction usually still looks plausible.
| Step | Expression | What it means physically |
|---|---|---|
| Inner loop closed | 1/(s + 2.5) | The plant pole moves from −2 to −2.5 |
Cascade with G_1 | 10/[s(s + 2.5)] | A type-1 loop, so no steady-state step error |
| Unity loop closed | 10/(s² + 2.5s + 10) | Second order, so every standard formula applies |
| Read the parameters | ω_n = 3.162, ζ = 0.395 | Overshoot 25.9 %, which the minor loop exists to reduce |
Signal Flow Graphs and Mason's Gain Formula
A signal flow graph is the same information as a block diagram with the blocks turned into labelled arrows and the summing junctions into nodes, and its point is that Mason's gain formula then reads the answer off without any rearrangement. The formula is T = Σ_k (P_k Δ_k) / Δ, where P_k is the gain of the kth forward path, Δ = 1 − Σ(loop gains) + Σ(products of pairs of non-touching loops) − Σ(products of triples of non-touching loops) + …, and Δ_k is that same Δ computed with every loop that touches path k deleted. Two definitions carry all the risk: a loop gain includes the sign at its summing junction, so a negative feedback loop has a negative loop gain, and non-touching means sharing no node at all, not merely looking separate on the page.
Apply it to the very system reduced above, as a check on both methods. There is one forward path, P_1 = G_1G_2. There are two loops: the minor loop L_1 = −G_2H_1 and the outer loop L_2 = −G_1G_2. They share the node between G_1 and G_2, so they touch, and there is no non-touching product to add. Hence Δ = 1 + G_2H_1 + G_1G_2, Δ_1 = 1, and T = G_1G_2/(1 + G_2H_1 + G_1G_2). Substitute G_1 = 10/s, G_2 = 1/(s + 2) and H_1 = 0.5: the numerator is 10/[s(s + 2)], the denominator is [s(s + 2) + 0.5s + 10]/[s(s + 2)], and the common factor cancels to leave T = 10/(s² + 2.5s + 10) — identical to the block-diagram result, which is the point of doing it twice.
Mason earns its keep when loops do not touch, because that is exactly the case block-diagram reduction handles clumsily. Consider a chain G_1 → G_2 → G_3 → G_4 from input to output with a local feedback −H_1 around G_2 and another −H_2 around G_4. The loops are L_1 = −G_2H_1 and L_2 = −G_4H_2, and they share no node, so the pair product enters with a plus sign: Δ = 1 + G_2H_1 + G_4H_2 + G_2H_1G_4H_2 = (1 + G_2H_1)(1 + G_4H_2). The single forward path touches both loops, so Δ_1 = 1 and T = G_1G_2G_3G_4/[(1 + G_2H_1)(1 + G_4H_2)] — which is just the product of two independently closed loops, exactly as intuition demands. Put numbers on it: with G_1 = 2, G_2 = 5, G_3 = 3, G_4 = 4, H_1 = 0.2 and H_2 = 0.5, the denominators are 1 + 1 = 2 and 1 + 2 = 3, so T = 120/6 = 20.
| Term | Symbolic value | With the numbers given |
|---|---|---|
Forward path P_1 | G_1G_2G_3G_4 | P_1 = 2 × 5 × 3 × 4 = 120 |
Loop L_1 | −G_2H_1 | L_1 = −1.0 |
Loop L_2 | −G_4H_2 | L_2 = −2.0 |
| Non-touching pair product | L_1L_2 = G_2H_1G_4H_2 | L_1L_2 = +2.0 |
Determinant Δ | 1 − (L_1 + L_2) + L_1L_2 | (1 + G_2H_1)(1 + G_4H_2) = 2 × 3 = 6 |
Overall gain T | P_1Δ_1/Δ with Δ_1 = 1 | T = 120/6 = 20 |
Δ, and gets a denominator that no block-diagram reduction can reproduce. Test it properly by listing the nodes of each loop and intersecting the lists — if they share even the input or output node of a shared block, they touch. The same discipline applies to Δ_k: delete from Δ every loop touching the forward path, which in most single-path problems removes all of them and leaves Δ_k = 1. When a graph has two forward paths and one loop touching only the second, Δ_1 and Δ_2 genuinely differ, and that is the case worth working slowly.Transient Response: Six Numbers from Two
For a first-order system 1/(1 + sτ) there is only one number to know: the step response reaches 63.2 % of its final value in one time constant, 86.5 % in two, 95 % in three and 98.2 % in four, so a settling time to two per cent is 4τ and there is never any overshoot. For the standard second-order system everything follows from ζ and ω_n, and the six results below are the ones questions ask for. Compute them all for the system met earlier, T(s) = 25/(s² + 6s + 25), with ζ = 0.6, ω_n = 5 rad/s and ω_d = ω_n√(1 − ζ²) = 4 rad/s.
| Specification | Formula | Value here |
|---|---|---|
Delay time t_d | (1 + 0.7ζ)/ω_n, an approximation | 1.42/5 = 0.284 s |
Rise time t_r | (π − β)/ω_d with β = cos⁻¹ζ | (3.1416 − 0.9273)/4 = 0.554 s |
Peak time t_p | π/ω_d | 3.1416/4 = 0.785 s |
Peak overshoot M_p | exp(−ζπ/√(1 − ζ²)) | exp(−2.356) = 0.0948, that is 9.48 % |
| Settling time to 2 % | 4/(ζω_n) | 4/3 = 1.333 s |
| Settling time to 5 % | 3/(ζω_n) | 3/3 = 1.0 s |
Two structural readings of that table matter more than the arithmetic. Overshoot depends only on ζ — ω_n is nowhere in the formula — so scaling a system in time changes every duration and leaves the overshoot untouched: 9.48 % for ζ = 0.6 whether the system settles in a second or a microsecond. And settling time depends only on the product ζω_n, which is the real part of the pole pair, so a specification on settling time is a vertical line in the s-plane and a specification on overshoot is a pair of rays from the origin. That is exactly how a design region is drawn on a root locus, and it is the reason the two chapters of this section join where they do. The commonly quoted damping values follow the same logic: ζ = 0.707 gives about 4.3 % overshoot and is the usual compromise, while ζ = 0.5 gives about 16 %.
ω_n², so that the final value is one; if the numerator is 10 while the denominator's constant term is 25, the final value is 0.4 and an overshoot must be quoted as a percentage of that, not of one. And it assumes no finite zero, because a zero close to the pole pair increases the overshoot substantially — a system with a zero at −1 beside poles at −3 ± j4 will overshoot far more than 9.48 %, and the formula gives no warning. When a question's numerator has an s in it, stop and use the actual inverse transform.Steady-State Error and the System Type
Where transient analysis asks how the response gets there, steady-state analysis asks where it ends up, and for a unity-feedback loop the answer needs only one limit. The error is E(s) = R(s)/[1 + G(s)], and the final value theorem gives e_ss = lim_(s→0) sR(s)/[1 + G(s)]. Evaluating that for the three standard inputs produces the three error constants: K_p = lim G(s) for a step, K_v = lim sG(s) for a ramp, and K_a = lim s²G(s) for a parabola. The system type is simply the number of poles G(s) has at the origin, and it decides which constants are finite: type 0 has a finite K_p, type 1 an infinite K_p and a finite K_v, type 2 an infinite K_v and a finite K_a.
Two worked cases fix the pattern. Take the type-1 loop G(s) = 20/[s(s + 2)(s + 5)] with unity feedback. Then K_p = lim G(s) = ∞, so the step error is 1/(1 + K_p) = 0 — a type-1 system tracks a step exactly, eventually. Next K_v = lim sG(s) = 20/(2 × 5) = 2, so a unit-ramp input leaves a constant error of 1/K_v = 0.5: the output runs parallel to the ramp, half a unit behind, for ever. And K_a = lim s²G(s) = 0, so a parabolic input leaves an error that grows without bound. Now remove the pole at the origin to get the type-0 loop G(s) = 20/[(s + 2)(s + 5)]. Now K_p = 20/10 = 2, so the step error is 1/(1 + 2) = 0.333 — a third of the command is never delivered — and the ramp error is infinite.
| System type | Unit step | Unit ramp | Unit parabola |
|---|---|---|---|
Type 0, e.g. 20/[(s+2)(s+5)] | 1/(1 + K_p) = 0.333 | Infinite | Infinite |
Type 1, e.g. 20/[s(s+2)(s+5)] | Zero | 1/K_v = 0.5 | Infinite |
| Type 2 | Zero | Zero | 1/K_a, finite |
E(s) = R(s) − C(s) in a loop whose feedback path is exactly 1. If the question's feedback path is H(s) = 0.5, the loop's own error signal is the difference between the command and half the output, so a zero error signal means the output has settled at twice the command — a system that is perfectly accurate about the wrong thing. In that case either recompute the true error R − C from the closed-loop transfer function directly, or convert the loop to an equivalent unity-feedback form first and use GH in place of G in the constants. A second, quieter version of the same trap is a question that raises the gain to reduce the steady-state error: 1/(1 + K_p) does fall as the gain rises, but so does the damping, so the reduction is paid for in overshoot and eventually in stability — which is exactly why an integral term, and not more gain, is the standard cure in the next chapter.Frequency Response, and What It Shares With the Time Domain
The frequency response of an LTI system is T(jω), obtained by substituting s = jω, and it is the steady-state gain and phase seen by a sinusoid at each frequency. Three numbers describe a closed-loop response and all three are computable from ζ and ω_n. The resonant peak M_r = 1/[2ζ√(1 − ζ²)] is the maximum of the magnitude, occurring at the resonant frequency ω_r = ω_n√(1 − 2ζ²). The bandwidth ω_B is where the magnitude falls to 1/√2 of its low-frequency value, that is by 3 dB, and for the standard second-order system it is ω_B = ω_n√[1 − 2ζ² + √(4ζ⁴ − 4ζ² + 2)]. For the running example with ζ = 0.6 and ω_n = 5: ω_r = 5√0.28 = 2.646 rad/s, M_r = 1/(2 × 0.6 × 0.8) = 1.042, which is 0.35 dB, and ω_B = 5√1.3185 = 5.74 rad/s.
Three consequences of those formulas are examinable in their own right. First, ω_r is real only when 1 − 2ζ² > 0, that is when ζ < 1/√2 = 0.707, so a system damped at 0.707 or more has no resonant peak at all and its magnitude falls monotonically — which is the frequency-domain statement of why ζ = 0.707 is the standard compromise. Second, ω_r is always below ω_d, and both are below ω_n, so the three frequencies must never be used interchangeably: here they are 2.646, 4 and 5 rad/s. Third, bandwidth and speed measure the same thing from two sides — ω_B is roughly proportional to ω_n for fixed damping, so a faster rise time and a wider bandwidth are the same requirement, and a demand for both a fast response and a narrow noise bandwidth is a demand to be traded, not satisfied.
| Frequency | Definition | Value |
|---|---|---|
Undamped natural, ω_n | Distance of the poles from the origin | 5 rad/s |
Damped natural, ω_d | ω_n√(1 − ζ²), the ringing frequency in time | 4 rad/s |
Resonant, ω_r | ω_n√(1 − 2ζ²), where the magnitude peaks | 2.646 rad/s |
Bandwidth, ω_B | Where the magnitude is 3 dB down | 5.74 rad/s |
ζ = 0.6 gives a phase margin of 59.2°, which is why the working rule ζ ≈ PM/100 is quoted so often: a phase margin of about 60° corresponds to ζ ≈ 0.6 and an overshoot near ten per cent, and a phase margin of 30° to ζ ≈ 0.3 and an overshoot near thirty-five. That correspondence is what makes frequency-domain design worth doing at all — the open-loop Bode plot is easy to sketch and easy to modify with a compensator, and the margin you read off it predicts the closed-loop transient you actually care about. It is exact only for the standard second-order system, so treat it as a design guide and not as a formula to be quoted in a numerical answer.Key takeaways
- Feedback trades gain for insensitivity: with
G = 100andH = 1the closed-loop gain is 0.9901, and a 10 % plant drift shows up as 0.11 % because sensitivity is1/(1 + GH). - Read
ω_nandζoff the denominator before anything else:25/(s² + 6s + 25)givesω_n = 5,ζ = 0.6and poles at−3 ± j4. - Reduce the innermost loop first: the two-loop example collapses to
10/(s² + 2.5s + 10), that isζ = 0.395and 25.9 % overshoot, and Mason's formula gives the identical result. - In Mason's formula a loop gain carries its own sign, and non-touching means sharing no node — the two-loop chain gave
Δ = 6andT = 20. - Overshoot depends only on
ζand settling time only onζω_n: 9.48 %,t_p = 0.785 sandt_s = 1.333 sfor the running example. - System type is the count of poles at the origin:
20/[s(s+2)(s+5)]hasK_v = 2, so zero step error and a ramp error of 0.5, while the same loop without the origin pole leaves a step error of 0.333. - A resonant peak exists only for
ζ < 0.707; for the exampleω_r = 2.646andω_d = 4sit belowω_n = 5whileω_B = 5.74 rad/ssits above it, so the four are never interchangeable.
Practice questions (8)
Attempt each one before opening the answer. Every explanation names the tempting wrong option as well as the right one, because that is where marks are lost.
A closed-loop transfer function is T(s) = 64/(s^2 + 12.8 s + 64). What is its damping ratio?
Show answer
Answer: D — 0.8
Match the denominator against the standard form s^2 + 2 z w_n s + w_n^2. The constant term gives w_n^2 = 64, so w_n = 8 rad/s, and the coefficient of s gives 2 z w_n = 12.8, so z = 12.8/16 = 0.8, which is underdamped. The tempting 1.6 is 12.8/8, obtained by dividing the s coefficient by w_n and forgetting the factor of two that the standard form carries; 6.4 is half the s coefficient, which is the product z w_n rather than z on its own, and 0.4 halves the correct answer a second time. A quick check is the pole pair at -z w_n plus or minus j w_n root(1 - z^2) = -6.4 plus or minus j4.8, whose distance from the origin is 8 as it must be.A unity-feedback loop has forward transfer function G(s) = 36/[s(s + 4.8)] and is driven by a unit step. How long does its output take to settle within two per cent of its final value?
Show answer
Answer: A — 1.67 s
Close the loop first: T(s) = G/(1 + G) = 36/(s^2 + 4.8 s + 36). Reading the standard form off that denominator gives w_n^2 = 36, so w_n = 6 rad/s, and 2 z w_n = 4.8, so z = 0.4. The settling time to two per cent depends only on the real part of the pole pair, z w_n = 2.4, and is 4/(z w_n) = 4/2.4 = 1.67 s. The tempting 0.833 s is 4/4.8, produced by dividing four by the whole coefficient of s instead of by half of it, so it is short by exactly a factor of two. The value 1.25 s applies the five per cent criterion 3/(z w_n) instead of the two per cent one, and 0.667 s divides by w_n rather than by z w_n, which is the quantity that fixes the decay envelope.The open-loop transfer function of a unity-feedback system is G(s) = 50/[s(s + 2)(s + 5)]. A ramp command r(t) = t is applied. What constant error does the output eventually settle to behind the command?
Show answer
Answer: C — 0.2
For a ramp the relevant error constant is the velocity constant K_v = limit of s G(s) as s tends to zero, which is 50/(2 x 5) = 5, and the steady-state error is 1/K_v = 0.2. The output therefore runs parallel to the ramp, permanently one fifth of a unit behind it. The tempting 0.167 is 1/(1 + K_v), which is the formula for a step input and not for a ramp; mixing the two is the single commonest error here, and the giveaway is that the step formula must reduce to zero for a type-1 loop. The value 5.0 quotes the error constant itself rather than the error it produces, and 0 is the step error of this same loop, which is zero because it has one pole at the origin.A standard second-order closed-loop system has a damping ratio of 0.5 and an undamped natural frequency of 10 rad/s. At what frequency is its closed-loop magnitude response a maximum?
Show answer
Answer: B — 7.07 rad/s
The resonant frequency of the standard second-order system is w_r = w_n root(1 - 2 z^2) = 10 root(1 - 0.5) = 10 x 0.7071 = 7.07 rad/s. The tempting 8.66 rad/s is the damped natural frequency w_d = w_n root(1 - z^2) = 10 x 0.866, which is the ringing frequency seen in the time response and is always larger than the frequency at which the magnitude peaks. Note the ordering that this question is built on: w_r is below w_d, which is below w_n, so the three must never be used interchangeably. The peak exists at all only because z is below 0.707; at 0.707 the square root vanishes and the magnitude falls monotonically from its low-frequency value.A closed-loop system has a complex pole pair at -2 plus or minus j4 and a third real pole at -30, with unity d.c. gain and no finite zeros. Using the dominant-pole approximation, what peak overshoot does its unit-step response show?
Show answer
Answer: D — 20.8 %
The third pole at -30 is fifteen times further to the left than the pair's real part, so the pair is dominant and the second-order formulas apply. The pair's distance from the origin gives w_n = root(2^2 + 4^2) = root(20) = 4.472 rad/s, and the damping ratio is the real part over that, z = 2/4.472 = 0.4472. Then z/root(1 - z^2) = 2/4 = 0.5 exactly, so the overshoot is exp(-0.5 pi) = 0.208, that is 20.8 per cent. The tempting 16.3 per cent comes from taking the imaginary part 4 as w_n, which makes z = 0.5 and understates the overshoot; the imaginary part is w_d, not w_n. The value 24.5 per cent drops the root(1 - z^2) from the denominator of the exponent, and 9.5 per cent is the familiar figure for z = 0.6 quoted from memory rather than computed.In a block diagram a block of transfer function G is to be moved backwards, against the direction of signal flow, past a summing junction, and the overall input-output relation must be left unchanged. What must be done to the other signal entering that junction?
Show answer
Answer: B — It must be divided by G.
After the move the block G multiplies the sum of both branches instead of only one, so the branch that did not previously pass through G would be amplified by G that it never saw before. Dividing that branch by G cancels the extra factor exactly and leaves the output unchanged. The tempting multiply-by-G answer is the rule for the other rearrangement entirely: moving a take-off point backwards past a block G requires the branch leaving it to be multiplied by G, because that branch now taps a signal that has not yet been through the block. The two rules run in opposite directions, and a diagram rearranged the wrong way still looks plausible, which is why the direction must be stated before the algebra is started.The forward path of a unity-feedback system is G(s) = 12/[s^2 (s + 6)], and commands of three standard shapes are applied to it in turn: a step, a ramp, and the parabola r(t) = t^2/2. Which of the following describe what the output eventually does?
Show answer
Answer: A — Its steady-state error to a unit-ramp command is zero.; B — Its acceleration error constant is 2, so its error to the parabolic command r(t) = t^2/2 settles at 0.5.
System type is the number of open-loop poles at the origin, and this loop has two, so it is type 2. The velocity constant K_v = limit of s G(s) is then 12/[s(s+6)] evaluated at s tending to zero, which is infinite, so the ramp error 1/K_v is zero. The acceleration constant K_a = limit of s^2 G(s) = 12/6 = 2, so the parabolic error 1/K_a = 0.5. The position constant K_p = limit of G(s) is infinite for any type above zero, so the step error is zero and not 0.333; quoting a finite K_p here is the trap, because it silently demotes the loop to type 0 by counting only one of the two poles at the origin. Calling the loop type 1 makes the same miscount in the other direction.An amplifier of gain 400 is enclosed in a negative feedback loop whose feedback path has a constant gain of 0.05. A small fractional change occurs in the amplifier's own gain. What fraction of that change appears as a fractional change in the closed-loop gain?
Show answer
Answer: C — 0.0476
The sensitivity of the closed-loop gain to the forward gain is S = 1/(1 + G H), and with G = 400 and H = 0.05 the loop gain G H is 20, so S = 1/21 = 0.0476. A ten per cent drift in the amplifier therefore shows up as about half a per cent at the output, which is the whole point of closing the loop and is paid for by the gain itself falling from 400 to 400/21. The tempting 21.0 is the factor 1 + G H, which is what the gain is divided by and what the drift is divided by, but it is not a fraction and cannot be one. The value 0.0500 is simply the feedback factor H read off the question, and 0.952 is 1 - S, the fraction of the drift that the loop removes rather than the fraction that survives.